Back (Failure Cases)

1.2343 | X37CrMoV5-1 | AISI H11 thermal fatigue cracks

Numeric designation1.2343 | AISI H11
Chemical designationX37CrMoV5-1
Statethermal fatigue cracks
Etchingungeätzt

This forging tool shows considerable wear and tear due to thermal fatigue cracks. These reticular cracks occur as a result of high alternating thermal stresses, such as those that occur during forging or in die-casting molds. A clear oxidation of the crack flanks can be seen in the cross-section polish.