CW614N | CuZn39Pb3 Dezincification test according to DIN EN ISO 6509-1
Numeric designation | CW614N |
---|---|
Chemical designation | CuZn39Pb3 |
State | Dezincification test according to DIN EN ISO 6509-1 |
Etching | ungeätzt |
A sample of CuZn42 was examined in the dezincification test. The dezincification depth is about 1270 µm and is therefore (besides the Pb content) unsuitable for applications in the drinking water sector. The basic hardness is 142 HBW2.5/62.5.